Sample Draw with PID, IR, O2, CO, H2S, VOC and Super Toxic Sensor Options
GX-6000 - CALL FOR PRICING
5 Operating modes
Smallest 6 gas sample draw
2 Interchangeable smart sensor slots
4 PID options: 10.6 (2 ranges) eV, 10.0 eV, and 11.7 eV lamps
PID library of over 600 VOCs — Easily switch target VOC from customizable user list or a recently used list
Benzene specific version
PPM Leak Check mode
LEL sensor protection mode
Man-down alarm
Panic alarm
Auto display rotation
Peak-bar display
LED Light source
Internal sample pump
Light weight, small, rugged IP-67
Interchangeable battery packs
Operates up to 14 hours
Field replaceable sensors, batteries, filters and pump
Intrinsically safe ATEX / IECEx / cCSAus
The GX-6000 is a game changer. This powerful hand-held instrument is capable of simultaneously monitoring up to 6 gases. In addition to the standard 4 confined space gases which include combustibles, O2, CO, & H2S, the GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors. Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene. Four PID sensors are available, 10.0 eV, 10.6 eV (low or high range), and 11.7 eV. Any combination of two PID sensors can be installed. GX-6000 PID sensors are also resistant to humidity.
The GX-6000 has a rugged design built for the nastiest environments. It is equipped with a removable impact-resistant rubber boot and a dust and water resistant enclosure with an IP-67 rating. With 5 bright LED lights on 3 sides of the instrument, alarms are easily seen from a variety of perspectives. With vibration and loud audible alarm, GX-6000 will easily alert users when needed.
Sensors available: CL2, CO, CO2, HCN, H2S, NH3, NO2, PH3, SO2, and VOC (volatile organic compounds) Ammonia, Chlorine, Hydrogen Cyanide, Nitrogen Dioxide, Phosphine, Sulfur Dioxide, Carbon Dioxide, Methane, Hydrocarbon, Hydrogen Sulfide, Carbon Monoxide, and Oxygen Monitor.
6 Operating Modes
Normal Mode
Barhole Mode
Inert Mode
Leak Check
Snap Log Mode
Benzene Specific
Confined Space Entry
Hazmat Response Teams
Arson Investigation
Remediation Site
Perimeter Monitoring
Leak Detection
Landfill Monitoring
Winery Tank Entry
Gases & Detectable Ranges
Gas
Measuring Range
Reading Increment
Alarm Set Points
Accuracy (which ever is greater)
PID Sensors
10.6 Lamp
600 VOC’s
0 – 40,000 ppb
1 ppb: (< 5000 ppb) 10 ppb: (> 5,000 ppb)
A1: 5,000 ppb
± 10% of reading, ± 1 digit
A2: 10,000 ppb
0 – 4,000 ppm
0.1 ppm: (< 600 ppm) 1 ppm: (> 600 ppm)
A1: 400 ppm
A2: 1,000 ppm
10.0 Lamp
Benzene Specific
0.01 – 50 ppm
0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 50 ppm)
No Alarms
300 VOC’s
0 – 100 ppm
0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 100 ppm)
A1: 5 ppm A2: 10 ppm
11.7 Lamp
High Voltage Lamp
0 – 1000 ppm
0.1 ppm
A1: 400 ppm
A2: 1,000 ppm
Galvanic
Oxygen (O2)
0 – 40.0% Vol.
0.1% Vol.
A1: 19.5 Vol.
± 0.5% O2
A2: 23.5 Vol.
Electro Chemical
Carbon Monoxide (CO)
0 – 500 ppm
1 ppm
A1: 25 ppm
± 5% of reading or ± 5 ppm
A2: 50 ppm
TWA 25 ppm
STEL 200 ppm
Hydrogen Sulfide (H2S)
0 – 100.0 ppm
0.5 ppm
A1: 5.0 ppm
± 5% of reading or ± 2 ppm
A2: 30.0 ppm
TWA 1.0 ppm
STEL 5.0 ppm
Toxics (EC Sensors)
Ammonia (NH3)
0 – 400.0 ppm
0.5 ppm
A1: 25 ppm
± 10% of reading or ± 5% of full scale
A2: 50 ppm
Chlorine (Cl2)
0 – 10.00 ppm
0.05 ppm
A1: 0.5 ppm
A2: 1.0 ppm
Hydrogen Cyanide (HCN)
0 – 15.0 ppm
0.1 ppm
A1: 5 ppm
A2: 10 ppm
Nitrogen Dioxide (NO2)
0 – 20.00 ppm
0.05 ppm
A1: 3 ppm
A2: 6 ppm
Phosphine
0 – 20.00 ppm
0.01 ppm
A1: 0.30 ppm
A2: 1.00 ppm
Sulfur Dioxide (SO2)
0 – 99.90 ppm
0.05 ppm
A1: 2 ppm
A2: 5 ppm
IR Sensors
Carbon Dioxide (CO2)
0 – 10,000 ppm
20 ppm
A1: 5,000 ppm
± 5% of reading or ± 2% of full scale
TWA 5,000 ppm
0 – 10.00% Vol.
0.02%
A1: 0.50% Vol
A2: 3.00% Vol
STEL 3.00% Vol
TWA 0.50% Vol
Methane (CH4)
0 – 100% LEL 0 – 100% Vol.
1% LEL/ 0.5% Vol
A1: 10% LEL A2: 50% LEL
Hydrocarbons
0 – 100% LEL 0 – 30% Vol.
Catalytic
Hydrocarbons (CH4, std)
0 – 100% LEL
1% LEL
A1: 10%LEL
± 5% of reading or ± 2% LEL
A2: 50%LEL
Common Specifications
Alarm Types
Gas alarm
Man-down
Trouble
Low and high adjustable
1st – self reset 2nd – latching
Low flow Sensor connection Low battery Circuit error Calibration range
Sample Method
Sample draw pump, flow rate 0.45 LPM, 50 foot sample range
Display
Digital LCD, autobacklight, peak bar display, auto display rotation, and customize order of gases
Audible Alarm
95 dB at 1 ft.
Languages
English, Spanish, French, German, Italian, Japanese, Korean, Portuguese, Russian
Continuous Operation
14 hours on Lithium-ion battery pack. Complete recharge in 3 hours. 8 hours Alkaline battery pack (3 AA size within each pack)
Operating Temp. & Humidity
-4°F to 122°F (-20°C ~ +50℃), 0- 95% RH non condensing
Dimensions
2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm) 14 ounce (400g) (with lithium battery pack)
Case Material
Dust and water resistant with IP-67 approval (exclude sample hose and probe)
Safety Design / Approvals
Explosion proof: IECEx , ATEX , TIIS , cCSAus Explosion class :Ex ia IIC T4 Ga Others: CE Marking
Standard Features
2 Smart sensors slots auto recognize sensor changes Library of over 600 VOC’s User defined VOC list. Up to 30 frequently used Recent VOC list for last 8 selected gases Pump and circuit status indicators User & station ID selection menu Datalogging (interval, alarm trend, station and user ID) Snap logging – on demand data logging Demand zero / Auto zero BUMP and CAL expiration alarm Flashlight IrDA communication LEL sensor protection mode
Standard Accessories
• Rubber boot • Belt clip • Hand strap • Tapper nozzle• Probe with hydrophobic & dust filter 3’ teflon lined hose • Benzene pre-filter tubes and holder (benzene versions)
Optional Accessories
• SDM-6000 calibration station • Bundles with instrument carrying case and accessories • Flexible probes • Up to 50 foot sample hoses • Filter set • IrDA cable
Warranty
Two years material (including sensors) and workmanship. One year for Cl2 and PID sensor (Two months for 11.7 eV lamp)
Part Number
Description
07-6035
O-ring, P6 EPDM
07-6036
Gasket for top cover, EPDM Black
07-6037
Joint pump EPDM black
07-6038
Gasket for cover, EPDM black
07-6039
Joint pressure sensor, EPDM black
07-6040
Gasket for sensor cover, EPDM black
07-6041
Gasket for sensor cap, Fluorine-contained rubber Black
07-6042
Gasket for BUD-6000, EPDM black
07-6043
Gasket for pump, EPDM black
10-1089
Screw, 2 x 4.5 SUS
10-1093RK
Screw SUS304 M2x6
13-0112RK
Hand strap
13-0123
Belt clip with screws
17-1031
Taper nozzle, red
20-0326
Rubber protect cover
21-1833RK
Filter case assembly (GX-2012/6000/RP-2009)
21-1926, 1 ea 21-1926-01, 5 p
LCD protection film 5 pcs/pack
21-1928
RKI Housing assembly for EX
21-1929
Protection case, L-1225L black
21-1930
Sensor case
21-1931
Sensor cover assembly
21-1932
Top case assembly
21-1933
RKI Body case assembly for EX
29-6100
Water immersion sensing seal 1 pack = 10 pcs
30-0022RK
Pump RP-12 (GX-2012/6000/CO-FL1/RP- 2009)
30-1054RK
Vibration motor, A3BE-MT4
33-0159RK
Teflon filter 1 pack = 10 pcs, PF-060 (GX-2003/2012/6000/RP-6 RP-2009/GP-1000)
33-0560RK
PPB pellet for PIS-001 sensor
33-0562
HPPM pellet for PIS-002 sensor
33-1112RK
Filter (Metal mesh) 1 pack = 10 pcs (GX-2003/2012/6000/RP-6 RP-2009)
33-7102RK
Charcoal filter CF-1821-2 for CO sensor 1 pack = 5 pcs (GX-2009/2012/6000)
33-7114RK
H2S scrubber filter CF-6264-8 for LEL sensor 1 pack = 5 pcs
47-4001
Connector with cable, MAIN to SENSOR
49-1050RK
Silver oxide battery, SR616SW
49-1120
Alkaline battery (AA size) TOSHIBA
49-1619
Lithium-ion battery unit BUL-6000
49-1620
Alkaline battery unit, BUD-6000
49-2982-01
Battery charger unit BC-6000 (with AC adaptor)
51-1139
LCD module BTD-128160B-FBWB-G-G
51-1501RK
PID lamp 10.6eV LA4SM600
57-1286
Main PCB assembly
DES-3311-1
DES-3311-1 CO2 0-5vol% Sensor
DES-3311-2
DES-3311-2 HC 0-100%LEL 0-30vol% Sensor
ES-1821
CO sensor Sensor
ES-1827I
H2S sensor Sensor
ESS-03DH-HCN
ESS-03DH HCN 0-15ppm Sensor
ESS-03DH-NO2
ESS-03DH NO2 0-9ppm Sensor
ESS-03DH-SO2
ESS-03DH SO2 0-6ppm Sensor
NC-6264A
HC sensor Sensor
OS-BM2
O2 sensor Sensor
PID-001
PIS-001 Iso-buthylene 0-50000ppb Sensor
PID-002
PIS-002 Iso-buthylene 0-6000pm Sensor
Photoionization detectors are calibrated using isobutylene, but PID is a broadband VOC detection technique, with a sensitivity that differs for each VOC. If you know what VOC you are detecting, then the table below will allow you to calculate the concentration for your specific VOC. Remember, these are approximate values, so for best accuracy you should calibrate with the relevant VOC. Multiply the indicated concentration by the appropriate Relative Response value to provide an estimate of actual VOC concentration. Download a PDF of PID Response Chart
Chemical Name
Formula
CAS no.
lE, eV
11.7 eV
10.6 eV
10.0 eV
Acenaphthalene
C12H8
208-96-8
8.12
0.7
Acenaphthene
C12H10
83-32-9
7.80
0.7
Acetaldehyde
C2H4O
75-07-0
10.23
2
6
ZR
Acetamide
C2H5NO
60-35-5
9.69
NA
2
NA
Acetic acid
C2H4O2
64-19-7
10.66
4
28
ZR
Acetic anhydride
C4H6O3
108-24-7
10.14
2
4
NA
Acetoin
C4H8O2
513-86-0
~9.8
1.6
1.4
2.0
Acetone
C3H6O
67-64-1
9.69
1.7
1.17
1.20
Acetone cyanohydrin
C4H7NO
75-86-5
11.09
1
ZR
ZR
Acetonitrile
CH3CN
75-05-8
12.20
ZR
ZR
ZR
Acetophenone
C8H8O
98-86-2
9.29
0.8
0.8
0.8
Acetyl bromide
C2H3BrO
506-96-7
10.24
1.5
8.0
ZR
Acetylene
C2H2
74-86-2
11.40
2
ZR
ZR
Acetylglycine, N-
C4H7NO3
543-24-8
9.40
NA
NA
NA
Acrolein
C3H4O
107-02-8
10.22
1.2
3.2
NA
Acrylic acid
C3H4O2
79-10-7
10.60
3
21
ZR
Acrylonitrile
C3H3N
107-13-1
10.91
1.6
ZR
ZR
Alkanes, n-, C6+
CnH2n+2
N/A
~10
NA
1.2
NA
Allyl acetoacetate
C7H10O3
1118-84-9
~10
NA
1.5
ZR
Allyl alcohol
C3H6O
107-18-6
9.63
1.1
2.3
4
Allyl bromide
C3H5Br
106-95-6
9.96
NA
3
NA
Allyl chloride
C3H5Cl
107-05-1
10.05
0.9
3.3
16
Allyl glycidyl ether
C6H10O2
106-92-3
~10
NA
0.8
NA
Allyl propyl disulfide
C6H12S2
2179-59-1
~8.5
NA
0.4
NA
Allylamine
C3H7N
107-11-9
8.80
NA
0.8
NA
GX-6000 Software
GX-6000 datalogging program 30.5MB version 06125
GX-6000 Firmware Update Instructions (step by step procedure)
TWA Alarm Setting for continuous operation (step by step procedure for turning off TWA Alarms)
Manuals & Literature
GX-6000 Product Datatsheet
GX-6000 PID Datatsheet
GX-6000 Brochure
GX-6000 Quick Reference Card
GX-6000 Operator’s Manual
GX-6000 PID Operator’s Manual
GX-6000 Datalogging Manual
GX-6000 Continuous Operation Adapter
IrDA Cable Driver Installation Guide
PID Response Chart