Sample Draw with PID, IR, O2, CO, H2S, VOC and Super Toxic Sensor Options
GX-6000 - CALL FOR PRICING
- 5 Operating modes
- Smallest 6 gas sample draw
- 2 Interchangeable smart sensor slots
- 4 PID options: 10.6 (2 ranges) eV, 10.0 eV, and 11.7 eV lamps
- PID library of over 600 VOCs — Easily switch target VOC from customizable user list or a recently used list
- Benzene specific version
- PPM Leak Check mode
- LEL sensor protection mode
- Man-down alarm
- Panic alarm
- Auto display rotation
- Peak-bar display
- LED Light source
- Internal sample pump
- Light weight, small, rugged IP-67
- Interchangeable battery packs
- Operates up to 14 hours
- Field replaceable sensors, batteries, filters and pump
- Intrinsically safe ATEX / IECEx / cCSAus
The GX-6000 is a game changer. This powerful hand-held instrument is capable of simultaneously monitoring up to 6 gases. In addition to the standard 4 confined space gases which include combustibles, O2, CO, & H2S, the GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors. Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene. Four PID sensors are available, 10.0 eV, 10.6 eV (low or high range), and 11.7 eV. Any combination of two PID sensors can be installed. GX-6000 PID sensors are also resistant to humidity.
The GX-6000 has a rugged design built for the nastiest environments. It is equipped with a removable impact-resistant rubber boot and a dust and water resistant enclosure with an IP-67 rating. With 5 bright LED lights on 3 sides of the instrument, alarms are easily seen from a variety of perspectives. With vibration and loud audible alarm, GX-6000 will easily alert users when needed.
Sensors available: CL2, CO, CO2, HCN, H2S, NH3, NO2, PH3, SO2, and VOC (volatile organic compounds) Ammonia, Chlorine, Hydrogen Cyanide, Nitrogen Dioxide, Phosphine, Sulfur Dioxide, Carbon Dioxide, Methane, Hydrocarbon, Hydrogen Sulfide, Carbon Monoxide, and Oxygen Monitor.
6 Operating Modes
- Normal Mode
- Barhole Mode
- Inert Mode
- Leak Check
- Snap Log Mode
- Benzene Specific
- Confined Space Entry
- Hazmat Response Teams
- Arson Investigation
- Remediation Site
- Perimeter Monitoring
- Leak Detection
- Landfill Monitoring
- Winery Tank Entry
Gases & Detectable Ranges
Gas Measuring Range Reading Increment Alarm Set Points Accuracy (which ever is greater) PID Sensors 10.6 Lamp 600 VOC’s 0 – 40,000 ppb 1 ppb: (< 5000 ppb) 10 ppb: (> 5,000 ppb) A1: 5,000 ppb ± 10% of reading, ± 1 digit A2: 10,000 ppb 0 – 4,000 ppm 0.1 ppm: (< 600 ppm) 1 ppm: (> 600 ppm) A1: 400 ppm A2: 1,000 ppm 10.0 Lamp Benzene Specific 0.01 – 50 ppm 0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 50 ppm) No Alarms 300 VOC’s 0 – 100 ppm 0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 100 ppm) A1: 5 ppm A2: 10 ppm 11.7 Lamp High Voltage Lamp 0 – 1000 ppm 0.1 ppm A1: 400 ppm A2: 1,000 ppm Galvanic Oxygen (O2) 0 – 40.0% Vol. 0.1% Vol. A1: 19.5 Vol. ± 0.5% O2 A2: 23.5 Vol. Electro Chemical Carbon Monoxide (CO) 0 – 500 ppm 1 ppm A1: 25 ppm ± 5% of reading or ± 5 ppm A2: 50 ppm TWA 25 ppm STEL 200 ppm Hydrogen Sulfide (H2S) 0 – 100.0 ppm 0.5 ppm A1: 5.0 ppm ± 5% of reading or ± 2 ppm A2: 30.0 ppm TWA 1.0 ppm STEL 5.0 ppm Toxics (EC Sensors) Ammonia (NH3) 0 – 400.0 ppm 0.5 ppm A1: 25 ppm ± 10% of reading or ± 5% of full scale A2: 50 ppm Chlorine (Cl2) 0 – 10.00 ppm 0.05 ppm A1: 0.5 ppm A2: 1.0 ppm Hydrogen Cyanide (HCN) 0 – 15.0 ppm 0.1 ppm A1: 5 ppm A2: 10 ppm Nitrogen Dioxide (NO2) 0 – 20.00 ppm 0.05 ppm A1: 3 ppm A2: 6 ppm Phosphine 0 – 20.00 ppm 0.01 ppm A1: 0.30 ppm A2: 1.00 ppm Sulfur Dioxide (SO2) 0 – 99.90 ppm 0.05 ppm A1: 2 ppm A2: 5 ppm IR Sensors Carbon Dioxide (CO2) 0 – 10,000 ppm 20 ppm A1: 5,000 ppm ± 5% of reading or ± 2% of full scale TWA 5,000 ppm 0 – 10.00% Vol. 0.02% A1: 0.50% Vol A2: 3.00% Vol STEL 3.00% Vol TWA 0.50% Vol Methane (CH4) 0 – 100% LEL 0 – 100% Vol. 1% LEL/ 0.5% Vol A1: 10% LEL A2: 50% LEL Hydrocarbons 0 – 100% LEL 0 – 30% Vol. Catalytic Hydrocarbons (CH4, std) 0 – 100% LEL 1% LEL A1: 10%LEL ± 5% of reading or ± 2% LEL A2: 50%LEL Common Specifications
Alarm Types Gas alarm Man-down Trouble Low and high adjustable 1st – self reset 2nd – latching Low flow Sensor connection Low battery Circuit error Calibration range Sample Method Sample draw pump, flow rate 0.45 LPM, 50 foot sample range Display Digital LCD, autobacklight, peak bar display, auto display rotation, and customize order of gases Audible Alarm 95 dB at 1 ft. Languages English, Spanish, French, German, Italian, Japanese, Korean, Portuguese, Russian Continuous Operation 14 hours on Lithium-ion battery pack. Complete recharge in 3 hours. 8 hours Alkaline battery pack (3 AA size within each pack) Operating Temp. & Humidity -4°F to 122°F (-20°C ~ +50℃), 0- 95% RH non condensing Dimensions 2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm) 14 ounce (400g) (with lithium battery pack) Case Material Dust and water resistant with IP-67 approval (exclude sample hose and probe) Safety Design / Approvals Explosion proof: IECEx , ATEX , TIIS , cCSAus Explosion class :Ex ia IIC T4 Ga Others: CE Marking Standard Features 2 Smart sensors slots auto recognize sensor changes Library of over 600 VOC’s User defined VOC list. Up to 30 frequently used Recent VOC list for last 8 selected gases Pump and circuit status indicators User & station ID selection menu Datalogging (interval, alarm trend, station and user ID) Snap logging – on demand data logging Demand zero / Auto zero BUMP and CAL expiration alarm Flashlight IrDA communication LEL sensor protection mode Standard Accessories • Rubber boot • Belt clip • Hand strap • Tapper nozzle• Probe with hydrophobic & dust filter 3’ teflon lined hose • Benzene pre-filter tubes and holder (benzene versions) Optional Accessories • SDM-6000 calibration station • Bundles with instrument carrying case and accessories • Flexible probes • Up to 50 foot sample hoses • Filter set • IrDA cable Warranty Two years material (including sensors) and workmanship. One year for Cl2 and PID sensor (Two months for 11.7 eV lamp) Part Number Description 07-6035 O-ring, P6 EPDM 07-6036 Gasket for top cover, EPDM Black 07-6037 Joint pump EPDM black 07-6038 Gasket for cover, EPDM black 07-6039 Joint pressure sensor, EPDM black 07-6040 Gasket for sensor cover, EPDM black 07-6041 Gasket for sensor cap, Fluorine-contained rubber Black 07-6042 Gasket for BUD-6000, EPDM black 07-6043 Gasket for pump, EPDM black 10-1089 Screw, 2 x 4.5 SUS 10-1093RK Screw SUS304 M2x6 13-0112RK Hand strap 13-0123 Belt clip with screws 17-1031 Taper nozzle, red 20-0326 Rubber protect cover 21-1833RK Filter case assembly (GX-2012/6000/RP-2009) 21-1926, 1 ea 21-1926-01, 5 p LCD protection film 5 pcs/pack 21-1928 RKI Housing assembly for EX 21-1929 Protection case, L-1225L black 21-1930 Sensor case 21-1931 Sensor cover assembly 21-1932 Top case assembly 21-1933 RKI Body case assembly for EX 29-6100 Water immersion sensing seal 1 pack = 10 pcs 30-0022RK Pump RP-12 (GX-2012/6000/CO-FL1/RP- 2009) 30-1054RK Vibration motor, A3BE-MT4 33-0159RK Teflon filter 1 pack = 10 pcs, PF-060 (GX-2003/2012/6000/RP-6 RP-2009/GP-1000) 33-0560RK PPB pellet for PIS-001 sensor 33-0562 HPPM pellet for PIS-002 sensor 33-1112RK Filter (Metal mesh) 1 pack = 10 pcs (GX-2003/2012/6000/RP-6 RP-2009) 33-7102RK Charcoal filter CF-1821-2 for CO sensor 1 pack = 5 pcs (GX-2009/2012/6000) 33-7114RK H2S scrubber filter CF-6264-8 for LEL sensor 1 pack = 5 pcs 47-4001 Connector with cable, MAIN to SENSOR 49-1050RK Silver oxide battery, SR616SW 49-1120 Alkaline battery (AA size) TOSHIBA 49-1619 Lithium-ion battery unit BUL-6000 49-1620 Alkaline battery unit, BUD-6000 49-2982-01 Battery charger unit BC-6000 (with AC adaptor) 51-1139 LCD module BTD-128160B-FBWB-G-G 51-1501RK PID lamp 10.6eV LA4SM600 57-1286 Main PCB assembly DES-3311-1 DES-3311-1 CO2 0-5vol% Sensor DES-3311-2 DES-3311-2 HC 0-100%LEL 0-30vol% Sensor ES-1821 CO sensor Sensor ES-1827I H2S sensor Sensor ESS-03DH-HCN ESS-03DH HCN 0-15ppm Sensor ESS-03DH-NO2 ESS-03DH NO2 0-9ppm Sensor ESS-03DH-SO2 ESS-03DH SO2 0-6ppm Sensor NC-6264A HC sensor Sensor OS-BM2 O2 sensor Sensor PID-001 PIS-001 Iso-buthylene 0-50000ppb Sensor PID-002 PIS-002 Iso-buthylene 0-6000pm Sensor Photoionization detectors are calibrated using isobutylene, but PID is a broadband VOC detection technique, with a sensitivity that differs for each VOC. If you know what VOC you are detecting, then the table below will allow you to calculate the concentration for your specific VOC. Remember, these are approximate values, so for best accuracy you should calibrate with the relevant VOC. Multiply the indicated concentration by the appropriate Relative Response value to provide an estimate of actual VOC concentration. Download a PDF of PID Response Chart
Chemical Name
Formula
CAS no.
lE, eV
11.7 eV
10.6 eV
10.0 eV
Acenaphthalene
C12H8
208-96-8
8.12
0.7
Acenaphthene
C12H10
83-32-9
7.80
0.7
Acetaldehyde
C2H4O
75-07-0
10.23
2
6
ZR
Acetamide
C2H5NO
60-35-5
9.69
NA
2
NA
Acetic acid
C2H4O2
64-19-7
10.66
4
28
ZR
Acetic anhydride
C4H6O3
108-24-7
10.14
2
4
NA
Acetoin
C4H8O2
513-86-0
~9.8
1.6
1.4
2.0
Acetone
C3H6O
67-64-1
9.69
1.7
1.17
1.20
Acetone cyanohydrin
C4H7NO
75-86-5
11.09
1
ZR
ZR
Acetonitrile
CH3CN
75-05-8
12.20
ZR
ZR
ZR
Acetophenone
C8H8O
98-86-2
9.29
0.8
0.8
0.8
Acetyl bromide
C2H3BrO
506-96-7
10.24
1.5
8.0
ZR
Acetylene
C2H2
74-86-2
11.40
2
ZR
ZR
Acetylglycine, N-
C4H7NO3
543-24-8
9.40
NA
NA
NA
Acrolein
C3H4O
107-02-8
10.22
1.2
3.2
NA
Acrylic acid
C3H4O2
79-10-7
10.60
3
21
ZR
Acrylonitrile
C3H3N
107-13-1
10.91
1.6
ZR
ZR
Alkanes, n-, C6+
CnH2n+2
N/A
~10
NA
1.2
NA
Allyl acetoacetate
C7H10O3
1118-84-9
~10
NA
1.5
ZR
Allyl alcohol
C3H6O
107-18-6
9.63
1.1
2.3
4
Allyl bromide
C3H5Br
106-95-6
9.96
NA
3
NA
Allyl chloride
C3H5Cl
107-05-1
10.05
0.9
3.3
16
Allyl glycidyl ether
C6H10O2
106-92-3
~10
NA
0.8
NA
Allyl propyl disulfide
C6H12S2
2179-59-1
~8.5
NA
0.4
NA
Allylamine
C3H7N
107-11-9
8.80
NA
0.8
NA
GX-6000 Software
GX-6000 datalogging program 30.5MB version 06125
GX-6000 Firmware Update Instructions (step by step procedure)
TWA Alarm Setting for continuous operation (step by step procedure for turning off TWA Alarms)Manuals & Literature
GX-6000 Product Datatsheet GX-6000 PID Datatsheet GX-6000 Brochure GX-6000 Quick Reference Card GX-6000 Operator’s Manual GX-6000 PID Operator’s Manual GX-6000 Datalogging Manual GX-6000 Continuous Operation Adapter IrDA Cable Driver Installation Guide PID Response Chart