Stand Alone Explosion Proof Transmitter
M2A DETECTOR HEAD - CALL FOR PRICING
Features
- Operates with or without a controller
- Direct digital readout with OLED cold temperature display
- Available gases include
◦ LEL, O2, H2S, CO, CO2, and 100% Vol CH4
◦ Toxic gases include NH3, AsH3, Cl2, ClO2, HCN, NO2, & SO2 - Infrared sensor for combustibles and CO2
- 4-20 mA & digital Modbus outputs standard
- 2 fully programmable alarm relays & fail relay
- Non-intrusive calibration via magnetic wand
- Explosion proof construction
- Patented water repellent sensor cover
- User friendly setup, push buttons & OLED menus
- Long-life sensors (2 + years typical)
The original M2A has been replaced with the M2A-XL Stand Alone Transmitter. The M2A-XL has an alternate housing, which is slightly taller, wider and deeper, but the electronics and operation are the same as the original M2A housing. Since this housing is deeper than the original M2A, longer standoffs are required inside to properly bring the display up to the transmitter’s window.
Changes related to using the new, alternate housing are outlined below:
- M2A-XL is the new model name for the original M2As installed in the larger housing. The new model name is visible on the label around the display.
- The Manual is different. The dimensional drawings have been revised to reflect the larger enclosure.
- New part numbers are utilized for the M2A-XL. The letters “XL” are replacing the “RK” within the former M2A part #’s.
- Inside the M2A-XL the electronics and operation are exactly the same as the original M2A.
The only difference is the larger enclosure. - The original M2A has been discontinued. As a result, the original M2A sections of the current price book were removed and replaced with the M2A-XL price list sections.
For more information and ordering, please see M2A-XL Stand Alone Transmitter
Related Services
Fixed Systems Turnkey Solutions
- Design, Consultations, and Engineering
- Installation
- Start-up
- Training
- System Maintenance
- Petrochemical plants
- Refineries
- Water & wastewater treatment plants
- Pulp & paper mills
- Manufacturing facilities
- Automotive
- Semiconductor plants
- Chemical plants
Specifications - Explosion Proof Transmitters (Class I, Div. 1 , Groups B, C, D)
Combustibles LEL
H2 SpecificO2
OxygenH2S
Hydrogen SulfideCO
Carbon MonoxideCH4
MethaneHC
HydrocarbonsCO2
Carbon DioxideLEL PPM Part# UL 65-2640RK 65-2647RK 65-2641RK 65-2643RK-05 65-2645RK-05 65-2646RK-05 65-2649RK-CH4 65-2658RK-CH4
65-2649RK-HC 65-2660RK-02 65-2660RK-03
65-2660RK-05
65-2660RK-10
CSA 65-2640RK-05 65-2647RK-05 65-2641RK-05 Sensors Catalytic Galvanic cell Electrochemical Infrared Measuring Ranges 0 – 100% LEL 0 – 9000
ppmCH40 – 100%
LEL0 – 25.0% Vol. 0 – 100 ppm 0 – 300 ppm 0 – 100% LEL 0 – 100% Vol.
0 – 100% LEL -02 0 – 5000 ppm -03 -05
0 – 5% Vol. 0 – 50% Vol.
-10 0 – 100% Vol. Resolution 1% LEL 20 ppm 1% LEL 0.1% Vol. 1 ppm 1% LEL / 1% Vol. 20 ppm / 0.01% Vol / 0.1% Vol. / 1% Vol. Lower Detectable Limit (LDL) 2% of full scale 0.1% Vol. 2% of full scale Max Current Draw (24VDC) 160 mA with alarm 1 and alarm 2 active and all relays energized 125 mA with alarm 1 and alarm 2 active and all relays energized
160 mA with alarm 1 and alarm 2 active and all relays energized
Response Time (T-90) 35 Seconds or less 90 Seconds
or less60 Seconds
or less90 Seconds
or less30 Seconds or less Life Expectancy 2 to 3 years with normal service 3 to 5 years with normal service 2 to 3 years with normal service 5 years plus with normal service Accuracy
(which ever is greater)± 5% of reading or ± 2% of full scale ± 0.5% Vol. O2 ± 5% of
reading or
± 2 ppm H2S± 5% of
reading or
± 5 ppm CO± 5% of reading or ± 2 % of full scale Weather Resistant Patented water repellent sensor coating Alarms Alarm Settings Two fully programmable alarm set points, increasing / decreasing, latching /
self-resetting, on delays, off delays, normally energized or de-energizedAlarm Indication Visual LEDs. Alarm 1, Amber; Alarm 2, Red; Fail, Red Relays 5 amp form ‘C’ contacts for alarm 1, alarm 2, and fail Physical Dimensions Height: 8.5” (215 mm), Width: 5.2” (132 mm), Depth: 4.5” (114 mm) Display Alphanumeric OLED display. 8 characters per line;
2 lines for gas concentration readout, plus user-friendly calibration and setupEnclosure Explosion proof for Class I, Div 1, Groups B, C, D. Enclosure Rating NEMA 4X, explosion proof, watertight, cast aluminum with o-ring seal and epoxy powder coating Controls Magnet used for calibration functions. Calibrates without opening the housing.
Internal push-button controls also available for calibration and setupOperating Environment Operating Temperature -40°F to 167°F -40°C to 75°C
-4°F to 113°F -20°C to 45°C
-40°F to 104°F -40°C to 40°C
23°F to 104°F -5°C to 40°C
-40°F to 122°F -40°C to 50°C
Relative Humidity 5 – 95% RH non-condensing Location Indoor or outdoor. Explosion proof for Class I, Div. 1, Groups B, C, D. Operating Voltage 10 VDC – 30 VDC Outputs Analog Linear 4-20 mA signal, into 1000 ohms impedance max (24DC), 0 – 500 ohms max (12VDC) corresponding to 0 – full scale Digital Modbus RTU output standard, fully configurable, 2-wire RS-485, 1200 to 19.2k baud Approvals C CSA US 65-2640RK-05
C CSA US65-2641RK-05
C CSA USControllers Beacon 110, Beacon 200, Beacon 410A, Beacon 800 as well as most DCS / PLC systems Warranty One year material and workmanship Specifications - Toxic Gas Transmitters (Class I, Div. 2)
O2
OxygenH2S
Hydrogen SulfideCO
Carbon MonoxideToxics CO2
Carbon DioxidePart# 65-2666RK *65-2644RK
65-2662RK 65-2663RK See Chart Below 65-2661RK-02 65-2661RK-03
65-2661RK-05
65-2661RK-10
Sensors Galvanic cell Electrochemical Infrared Measuring Ranges 0-25% Vol. 0-100 ppm 0-300 ppm See Chart Below -02 0 – 5000 ppm -03 -05
0 – 5% Vol. 0 – 50% Vol.
-10 0 – 100% Vol. Resolution 0.1% Vol. 1 ppm See Chart Below 20 ppm / 0.01% Vol. / 0.1% Vol. / 1%Vol. Lower Detectable Limit (LDL) 0.1% Vol. 2% of full scale Response Time (T-90) 35 Seconds or less 60 Seconds or less 30 Seconds or less Max Current Draw (24VDC) 125 mA with alarm 1 and alarm 2 active and all relays energized 160 mA with alarm 1 and alarm 2 active and all relays energized Life Expectancy 2 to 3 years with normal service 5 years plus Accuracy
(which ever is greater)± 0.5% Vol. O2 ± 5% of reading or
± 2 ppm H2S± 5% of reading or
± 5 ppm CO± 10% of reading or
± 5% of full scale± 5% of reading or
± 2% of full scaleAlarms Alarm Settings Two fully programmable alarm set points, increasing / decreasing, latching / self-resetting, on delays, off delays, normally energized or de-energized, Alarm Indication Visual LEDs. Alarm 1=Amber; Alarm 2=Red; Fail=Red Relays 5 Amp form ‘C’ contacts for alarm 1, alarm 2, and fail Physical Dimensions Height: 8.5” (215 mm), Width: 5.2” (132 mm), Depth: 4.5” (114 mm) Display Alphanumeric OLED display. 8 characters per line; 2 lines for gas concentration readout, plus user-friendly calibration and setup Sensor Rating Non explosion proof construction, designed for Class I, Div. 2, Groups B, C, D (no certification) Housing J-Box NEMA 4X, explosion proof, watertight, cast aluminum with o-ring seal and epoxy powder coating Controls Magnet used for calibration functions. Calibrates without opening the housing. Internal push-button controls also available for calibration and setup Sensor Aluminum / Plastic (non explosion proof) Operating Environment Operating Temperature -4°F to 113°F -20°C to 45°C
-40°F to 104°F -40°C to 40°C
23°F to 104°F -5°C to 40°C
14°F to 104°F -10°C to 40°C
-40°F to 122°F -40°C to 50°C
Relative Humidity 5 – 95% RH non-condensing Location Indoor or outdoor Operating Voltage 10 VDC – 30 VDC Outputs Analog Linear 4-20 mA signal, into 1000 ohms impedance max (24DC), 0 – 500 ohms max (12VDC) corresponding to 0 – full scale Digital Modbus RTU output standard, fully configurable, 2-wire RS-485, 1200 to 19.2k baud Controllers Beacon 110, Beacon 200, Beacon 410A, Beacon 800 as well as most DCS / PLC systems Warranty One year materials and workmanship Part Number With J-Box Gas Range Resolution Sensor Type 65-2670RK-NH3-75 Ammonia (NH3) 0 – 75.0 ppm 0.1 ppm CT-7 65-2670-NH3-1 Ammonia (NH3) 0 – 100 ppm 1 ppm CT-7 65-2670-NH3-2 Ammonia (NH3) 0 – 200 ppm 1 ppm CT-7 65-2670-NH3-5 Ammonia (NH3) 0 – 500 ppm 1 ppm CT-7 65-2670-NO2 Nitrogen Dioxide (NO2) 0 – 15.0 ppm 1 ppm CT-7 65-2648RK-AsH3 Arsine (AsH3) 0 – 1.50 ppm 0.1 ppm ESM -01 65-2670RK-CL2-3 Chlorine (Cl2) 0 – 3.00 ppm 0.01 ppm CT-7 65-2670RK-CL2-10 Chlorine (Cl2) 0 – 10.0 ppm 0.1 ppm CT-7 65-2670RK-CLO2 Chlorine Dioxide (ClO2) 0 – 1.00 ppm 0.01 ppm CT-7 65-2648RK-HCN Hydrogen Cyanide (HCN) 0 – 15.0 ppm 0.1 ppm ESM -01 65-2648RK-PH3 Phosphine (PH3) 0 – 1.00 ppm 0.01 ppm ESM -01 65-2648RK-SO2 Sulfur Dioxide (SO2) 0 – 6.00 ppm 0.01 ppm ESM -01 M2A Literature
Product Datasheet Operating Manuals M2A Datasheet M2A Operator’s Manual Spanish M2A Datasheet Spanish M2A Manual