3-Wire Explosion Proof Transmitter
VOC Pro – PID Detector Head - CALL FOR PRICING
Features
- PID sensor options: 10.0 eV lamp / 11.7 eV / 10.6 eV ppb / 10.6 eV ppm
- Wired power (3-Wire), 12 to 35 VDC operating voltage
- Operating temperature range -40°C to +54°C
- Graphical LCD with LED backlight
- 3 Push-button interface (ADD, MENU, SUB) with corresponding magnetic, non-intrusive switches
- 2 Individually configurable alarms
- 2 Front panel LED indicators (amber and red)
- 2 Optional fully programmable alarm relays (dry contacts)
- Output options: 4-20mA (3-wire) analog, RS-485 modbus (4 wire)
- 1-Year warranty (see specifications)
The VOC Pro Series Gas Detector is a versatile assembly that uses a PID sensor to detect a variety of gases. Wired power (12 to 35 VDC) with 4-20 mA analog and RS-485 Modbus outputs are standard. Magnetic switches allow for non-intrusive calibration while in the field as well as full system settings and diagnostics.
The VOC Pro represents the latest leading edge technology in fixed gas detection today.
Related Services
Fixed Systems Turnkey Solutions
- Design, Consultations, and Engineering
- Installation
- Start-up
- Training
- System Maintenance
- Petrochemical plants
- Refineries
- Water & wastewater treatment plants
- Pulp & paper mills
- Manufacturing facilities
- Automotive
- Semiconductor plants
- Chemical plants
Ranges Part# Suffix
PID Lamps 10.0 eV 11.7 eV 10.6 eV
low ppm10.6 eV ppm Part # Base 66-6195-XX 66-6194-XX 66-6192-XX 66-6193-XX 0 – 10.00 ppm -01 ▪ ▪ 0 – 20.00 ppm -02 ▪ ▪ 0 – 50.00 ppm -05 ▪ ▪ 0 – 100 ppm -10 ▪ ▪ ▪ 0 – 200 ppm -20 ▪ 0 – 500 ppm -50 ▪ 0 – 1000 ppm -1K ▪ 0 – 2000 ppm -2K ▪ Sensor Type PID Operating Voltage Wired power (3-Wire) 12 to 35 VDC Power Draw 2 Watts maximum Protection Power electromagnetic interference (EMI) filter 4-20 mA surge suppression
RS-485 surge suppression
Display Screen 102×64 Resolution graphical LCD screen transflective (sunlight readable) with white LED backlight Interface 3 Push-buttons (MENU, ADD and SUB) 3 Magnetic non-intrusive switches for calibration
Customizable Settings 2 Individual-configurable alarm LED/relay set-points Temperature Range -40°C to +54°C (-40°F to +130°F) Output (digital) RS-485 modbus Wired (Analog) Output 4-20 mA (3-Wire) Fault terminal
Optional 2 dry-contact relays with replaceable 4 amp fuses
Remote Sensor Kit (Optional Additional Feature)
Remote sensor kit with enclosure (5 pin) • PID sensor max. length: 35 feet
Product Dimensions 5.5 in, L x 6 in. W x 7 in. H (8 in. W x 17 in. H Max. dimensions with attachments) Total Weight 6 lbs. Hazardous Location Approvals
Main Enclosure Certified explosion / flame proof CQPSUS Class I, Division 1 & 2, Groups B, C & D,
Nema 3, 4, 4X, 7 (B, C, D) 9 (E, F, G)Temp.= -20°C to +60°C
Sensor Housing Certified explosion / flame proof CQPSUS Class I, Division 1 & 2, Groups B, C & D
Temp.= -40°C to +60°C
Controllers Compatible with all RKI Beacon controllers, as well as most DCS / PLC systems: Beacon 110, Beacon 200, Beacon 410A and Beacon 800, MC-6400 Warranty 1-Year warranty for electronics, and PID sensor (Two months for 11.7 eV lamp) Photoionization detectors are calibrated using isobutylene, but PID is a broadband VOC detection technique, with a sensitivity that differs for each VOC. If you know what VOC you are detecting, then the table below will allow you to calculate the concentration for your specific VOC. Remember, these are approximate values, so for best accuracy you should calibrate with the relevant VOC. Multiply the indicated concentration by the appropriate Relative Response value to provide an estimate of actual VOC concentration. Download a PDF of PID Response Chart
Chemical Name
Formula
CAS no.
lE, eV
11.7 eV
10.6 eV
10.0 eV
Acenaphthalene
C12H8
208-96-8
8.12
0.7
Acenaphthene
C12H10
83-32-9
7.80
0.7
Acetaldehyde
C2H4O
75-07-0
10.23
2
6
ZR
Acetamide
C2H5NO
60-35-5
9.69
NA
2
NA
Acetic acid
C2H4O2
64-19-7
10.66
4
28
ZR
Acetic anhydride
C4H6O3
108-24-7
10.14
2
4
NA
Acetoin
C4H8O2
513-86-0
~9.8
1.6
1.4
2.0
Acetone
C3H6O
67-64-1
9.69
1.7
1.17
1.20
Acetone cyanohydrin
C4H7NO
75-86-5
11.09
1
ZR
ZR
Acetonitrile
CH3CN
75-05-8
12.20
ZR
ZR
ZR
Acetophenone
C8H8O
98-86-2
9.29
0.8
0.8
0.8
Acetyl bromide
C2H3BrO
506-96-7
10.24
1.5
8.0
ZR
Acetylene
C2H2
74-86-2
11.40
2
ZR
ZR
Acetylglycine, N-
C4H7NO3
543-24-8
9.40
NA
NA
NA
Acrolein
C3H4O
107-02-8
10.22
1.2
3.2
NA
Acrylic acid
C3H4O2
79-10-7
10.60
3
21
ZR
Acrylonitrile
C3H3N
107-13-1
10.91
1.6
ZR
ZR
Alkanes, n-, C6+
CnH2n+2
N/A
~10
NA
1.2
NA
Allyl acetoacetate
C7H10O3
1118-84-9
~10
NA
1.5
ZR
Allyl alcohol
C3H6O
107-18-6
9.63
1.1
2.3
4
Allyl bromide
C3H5Br
106-95-6
9.96
NA
3
NA
Allyl chloride
C3H5Cl
107-05-1
10.05
0.9
3.3
16
Allyl glycidyl ether
C6H10O2
106-92-3
~10
NA
0.8
NA
Allyl propyl disulfide
C6H12S2
2179-59-1
~8.5
NA
0.4
NA
Allylamine
C3H7N
107-11-9
8.80
NA
0.8
NA
.......................... + MORE
VOC Pro Datasheet
VOC Pro Operator’s Manual
PID Response Chart for VOC’s